Digital Hybrid Wireless™ Modular Receiver System
Receivers 1&2 in Ratio Diversity Mode, Rest in
Switched Diversity Mode
Receiver Module
Frequency Locations
Cursor Select
Walk Test Recorder
The Walk Test Recorder offers a convenient method of
testing the operation of the selected receiver module (or
receiver module pair) with their corresponding transmit-
ters. The Walk Test Recorder makes a chart recording
of the RF signal strength aligned with an audio record-
ing of the receiver modules output.
Use the MC65 cable (supplied with unit) to connect the
PHONES jack output on the Venue Receiver front panel
to the computer system’s audio input.
Record Button
Stop Button
Click the Record button to start the Walk Test Recorder
and the Stop button to stop the recording process. It is
suggested to mention locations frequently during this
test to more easily identify problem areas.
Factory Defaults
Clicking this menu item restores the selected Venue
System to the factory default settings.
The Factory Default Settings are:
Under SetUpRx
Level +00 dBu
Phase NORMAL
TxBatt 9V ALK
SmartNR NORMAL
PilotBP NORMAL
Compat Digital Hybrid
Tuning NORMAL MODE
DivMode Switched
Under LockSet
Lockset NOT LOCKED
Delete VR
Clicking the Delete VR menu item deletes the current
Venue System from the VRpanel.