VR Field Wideband Receiver
LECTROSONICS, INC.
12
Resetting to Factory
Defaults
Resetting to Factory Defaults can be a time saver for
setting up the system. Start with the power turned off,
then hold Receiver Select Buttons 5 and 6 while power-
ing up the system.
POWER Switch
Receiver Select
Buttons 5 and 6
The Factory Default Settings are:
Level
+00 dBu
Level
+00 dBu
Phase
NORMAL
TxBatt
9V ALK
SmartNR
NORMAL
Compat
Dig. Hybrid
Tuning
NORMAL MODE
DivMode
Switched
LockSet
NOT LOCKED
RxCh
8, 0
System Setup with the LCD
It is generally best to complete these steps in the se-
quence shown.
• Selectcompatibilitymodes
• SelectSmartNoiseReductionmode
(for Digital Hybrid Compat Mode only)
• Selectdiversitymodes
• Findclearchannelsandsettransmittersto
match the receivers
• Adjustaudiooutputlevel
• Selectaudiosignalphase
• Selecttransmitterbatterymonitoringmode
• Controlpanellockout
Selecting Compatibility Modes
Navigate to the Compat setup screen.
Six compatibility modes are available to match various
transmitter types. In this example, the Digital Hybrid
compatibility mode is selected for receiver module 1.
Press the Receiver Select button for each module and
rotate the MENU/SELECT control to select the mode.
The following modes are available:
Compat
Setup Mode
Description
Dig. Hybrid Lectrosonics Digital Hybrid (HYB)
Mode 3 Mode 3 (M.3) (call for details)
200 Series Lectrosonics 200 Series (200)
100 Series Lectrosonics 100 Series (100)
IFB Lectrosonics IFB Series (IFB)
Mode 6 Mode 6 (M.6) (call for details)
Mode 7 Mode 7 (M.7) (call for details)
Shortcut: Press and hold the Receiver Select
button under the selected module (module 1 in
the example above) then press the buttons under
the other modules that are to be set to the same
mode.
If you are using Digital Hybrid transmitters, set them
and the matching receiver modules to the Dig. Hybrid
mode for best performance.
Selecting the Noise Reduction Mode
When the Compat Mode is set to Digital Hybrid, three
settings are available that affect the high frequency
audio content and noise:
• NORMAL(factory default) applies a moderate
amount of noise reduction, dramatically reducing
hiss with virtually no discernible side effects.
• FULL applies more aggressive noise reduction with
transparency superior to the noise reduction system
used for many years in the earlier Lectrosonics
wide deviation analog systems.
• OFF applies no noise reduction for complete trans-
parency.
Navigate to the SmartNR setup screen.