Lectrosonics EQ1_EQ2 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
27 Band Automatic Equalizer
FRONT PANEL DESCRIPTION
LECTROSONICS, INC.
RIO RANCHO, NM U.S.A.
POWER
SAVE SELECT DOWN UP
Adjust EQ Curve
Band: 1K Level: 0
EQ1 Front Panel
LECTROSONICS, INC.
RIO RANCHO, NM U.S.A.
POWER
EQ2 Front Panel
EQ1 and EQ2
POWER SWITCH and LED - Indicates that the EQ1/EQ2 has AC power and is on.
EQ1 Only
LCD DISPLAY - Shows the available menus items for configuring the EQ1.
SAVE Button - Saves the current value of all EQ1 parameters to nonvolatile memory. Used if changes are
made from the front panel which should become permanent. If the SAVE button is not pressed after any
changes, the changes will be lost when the power is removed from the EQ1.
SELECT Button - Moves the active cursor between menu categories.
UP and DOWN Buttons - Increments or decrements the values in the active menu category. If the Up and
Down buttons are both pushed while the power is turned on, the EQ1 will be returned to factory default condition.
Factory defaults are as follows:
1) Stored EQ curve is reset to flat.
2) User Target curves 1-3 are reset to Factory curves 1-3.
3) Pop Suppress system is set to off.
4) LCD display contrast is set to the factory default.
5) Operational mode is set to Local.
EQ1 Menu Options:
EQ1 Address - Allows the LecNet address of the EQ1 to be changed. The factory default address is 131.
Adjust EQ Curve - Allows the cut or boost value of each of the 27 1/3 octave bands to be adjusted. Adjustment
range is +/-15dB.
Adjust Target Curve - Allows any of the three user programmable target curves (U1, U2, or U3) to be adjusted.
Adjustment range for any band is +/-15dB. Note that while no adjustment of the three factory curves (F1, F2,
and F3) is allowed, the factory values may be reviewed using this menu option.
Adjust Target Curve Input Source - Allows the input source associated with each of the user programmable
target curves (U1, U2, or U3) to be chosen. Note that while no change may be made to the input source of the
three factory curves (F1, F2, and F3), the factory values may be reviewed using this menu option.
EQ Status (EQ In/Out) - Bypasses the equalizer and low cut filter of the EQ1. This is useful for A/B compari-
sons between the equalized and unequalized systems.
Low Cut Filter (In/Out) - Bypasses the low cut filter of the EQ1.